Overview:
- Casing surveys with proper running gear provide the best directional measurement
- Use of a ccl or gamma-ray for wireline correlation ensures measured depth accuracy
- Pre-and-post job field calibrations monitor mass unbalance performance
- Drop surveys save time by enabling surveys while tripping

 

In-Run Quality Control
- Gyrocompass
    • Inclination QC is generally the same as with
- MWD systems
    • Comparison against theoretical ERH is the primary QC measure
    • Additional measures include gyro output stability and gyro bias stability.
- Continuous Surveying
    • Zero-velocity drift checks are used to compensate for bias, mass unbalance, and
- Earth Rate effects
    • QC measures ensure that drift variation matches predicted values

 

Gyrocompassing

....

View the entire Presentation:

Gyro Technology in Oil and Gas

 

Ben Hawkinson and Steve Mullin - SDC and Gyrodata

 