Why Exclusion Zones?

Problem With Drilling East/West

  • Axial Magnetic Interference (AMI) is dominant error source (Az)
  • 50% more error than Declination

Problems With the Corrections

  • Multiple solutions
  • Degraded accuracy

Available Corrections

  • Single Station Correction (SSC)
  • Multi-Station Analysis (MSA)

Exclusion Zones for Horizontal Wells

Existing Standards (SPE 125677):

  • BGGM
    • sin(Inc)*sin(Az) < 0.82
    • ±35° from East/West
  • IFR1
    • sin(Inc)*sin(Az) < 0.91
    • ±25° from East/West

Multiple Solutions

SSC Single Station Correction

  • Bx and By are measured

....

 

View the entire Presentation:

East-West Exclusion Zones: Why Do We Have Them and How Can We Eliminate Them?

 

Chad Hanak, Ph.D.

 

More from Meeting 44