Overview:

• Add the Bz test to the standard set of QC tests for nonaxial interference corrected surveys

• Evaluate the Bh & Bv QC tests

• ISCWSA peer review welcomed

 

Total Magnetic Field/Dip Test

• Earth’s magnetic field strength and dip angle calculated from tool’s magnetometer and accelerometer outputs

• Compared with the Reference Field values

• Error model estimations for the directional sensors and the reference field define how well the two should agree

 

Drilling at 90/90

• Azimuth is sensitive to axial interference, Bt and Dip are not

• Standard QC tests are insensitive to excessive axial interference
      – SPE 133417 (ISCWSA)

• Stimulus for finding new QC test

 

....

View the entire Presentation:

Alternative MWD Magnetic QC-test

 

Inge Edvardsen - Baker Hughes 

 

More from Meeting 33